All posts

Is my Sigfox device offline? How to notice a silent device

By Foxwatch · alerts, monitoring

Freezer B2 silent for 2 h 10 minResolvedNo uplinks08:0010:0012:0014:0016:00

A Sigfox device that stops working doesn’t send a goodbye message. It just goes quiet. The battery runs flat, the antenna gets knocked off, a container gets moved behind a steel wall. The backend shows the last message it received, and nothing tells you a message is overdue.

For a fleet of ten devices you might notice. For a fleet of a thousand, a silent device can go unnoticed for weeks, often until a customer asks why their readings stopped.

Know what “normal” looks like for each device

There’s no single right offline threshold, because devices send on very different schedules:

  • A tracker on the move might send every 10 minutes.
  • A temperature sensor might send every hour.
  • A water meter might send once a day.
  • An alarm sensor might send only a daily heartbeat, plus a message when something happens.

A one-hour threshold is sensible for the tracker and pure noise for the meter. Set the threshold per class of device, at roughly two to three times its normal interval. That allows for one lost message without a false alarm, while a real outage still gets caught within a reasonable time.

Missed messages are an early warning

Every Sigfox message carries a sequence number that counts up with each message the device sends. A gap in the sequence numbers means messages were sent but didn’t arrive. A device that’s still talking but losing more and more messages usually has a coverage or antenna problem, and it’s often about to go silent altogether. Watch the gaps, not only the silences.

#1040#1041#1042#1043missed#1044#1045

Alerts that open and close

The fastest way to make people ignore alerts is to send the same alert every five minutes. A better approach is to treat “offline” as a state with a start and an end:

  1. The device misses its threshold, and one alert opens.
  2. Nothing more is sent while it stays offline.
  3. The device sends a message again, and the alert resolves with one notification.

That way an alert in your inbox always means something changed, and the history shows how long each outage lasted.

Send it to the right people

An offline sensor at one customer site matters to that site’s maintenance contact, not to everyone on the team. Group the people who need to hear about each part of the fleet, and send each alert only to the group that can act on it.

Foxwatch alerts work this way: they’re stateful, so you get one notification when a device goes quiet and one when it comes back. You can scope a rule to a single device, a profile, a tag or the whole fleet, and action groups decide who gets told. Because Foxwatch keeps a shadow of every device, a device that’s gone silent still shows its last known readings.

Foxwatch keeps your Sigfox devices and their history, decodes their payloads and tells you when something needs attention. Try it on your own Sigfox account.